Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine

Product Details
Customization: Available
Type: RF Equipment
Theory: RF (Radio Frequency)
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 10 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (25)
  • Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
  • Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
  • Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
  • Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
  • Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
  • Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
Find Similar Products

Basic Info.

Model NO.
BR806
Application
Salon
Portable
Non Portable
Model Number
Br806
RF Frequency
2.78MHz
Temperature
35-55 Degree
Microneedles
Stainless
25 Needles Length
1.5/2.0/2.5mm(for Face)
49 Needles Length
2.0/2.5/3.0mm(for Body)
La Reina Tips
4 PCS(Eyes,Face,Forehead,Body)
Power
300W
AC Power
AC110V-220V
Single Treatment Area
0.5-3.5mm Length
Machine Size
42*56*106cm
Working Conditions
Ambient Temperature 25-35degree
Humidity
95%
Treatment Parts
Wholebody and Face
RF Source
Fractional Radio Frequency
Transport Package
Wooden Case
Specification
107X56X42 cm
Trademark
BEIR
Origin
China
HS Code
8543709990
Production Capacity
500PCS/Month

Product Description

2021 hot sale Fractional RF MicroNeedle Skin Tightening facial beauty machine
Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine

Theory
(1) Technical Theory
Introduce Israel's most advanced dot matrix radio frequency technology, use matrix needles to penetrate 0.5mm-3.5mm subcutaneously, and at the same time, each pulse emits radio frequency energy through multiple matrix points, which is directly heated under the skin; under the stimulation of matrix needles, subcutaneous produce a large amount of collagen, and use radio frequency to directly heat under the skin(65 degree-75 degree) to repair broken collagen fibers, so as to achieve a better repair effect.

(2) Treatment Theory 
Go deep into the tissue cells under the skin through the treatment port; generate a special 3D energy field, which acts on the elastic fibers and collagen fibers from the inside, activates the collagen and elastic fibers in the dormant state, quickly penetrates into the skin tissue cells, comprehensively reduces scars, and restores the skin elastic, sagging skin begins to appear firm.
Gene recombination fluid: effectively provide growth factors and nutrients needed in the process of skin tissue repair.



USER EFFECT

Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
MORE PHOTO WITH THE MACHINE



Treatment Steps

When doing treatment, the foot switch controls the treatment energy output. (Therapeutic energy output. After stepping on the pedal, release the pedal to hear a beep. The time for the sound is the energy output time.).
After hearing the beep, the second operation can be performed.

LA REINA
Clean the treatment area with warm water.
Smear the gel (sold separately) on the treatment area.
Turn on the machine and adjust to the appropriate parameters; starting from a low profile, energy 83 is generally available, and the highest is 127. Adjust the parameters according to the customer's feeling and skin reaction (reddish heat).
The handle moves from bottom to top according to skin texture. The working head moves slowly on the skin and should not stay on the skin to avoid scalding customers. Because the eye and forehead are less fat, the energy output intensity should be appropriately reduced.
Clean and disinfect the used working head after treatment.

Nursing time: The operation time is 15-25 minutes, one treatment is performed every 15 days, and a course of treatment is ten times.

 Pluma
Cleansing: Before treatment, cleanse the skin and cleanse deeply.
Skin epidermal anesthesia: apply anesthetic to the nursing area for epidermal anesthesia, and wrap it with plastic wrap to improve the effect of the anesthetic (about 30 minutes).
After scraping off the anesthetic, the treatment area can be disinfected with iodophor or geraniol.

 
Treatment Area Needle Length Normal Energy
Eyes 1.5mm Adjusted to 63, maximum energy 95
Forehead 1.5mm; 2.0mm Adjusted to 63, maximum energy 95
Face and Neck 2.0mm; 2.5mm Adjusted to 83, maximum energy 159
Abdomen 3.0mm Adjusted to 84, maximum energy 127

When treating the skin, you can choose a handle switch or a foot switch to control the treatment energy output. After stepping on the pedal or pressing the handle button, release the pedal to hear a beep. The time of the beep is the energy output time. The needle must be pulled out to proceed to the next step after hearing the beep.
The operation on the site of the operation only needs 1 to 2 times, and remember not to repeat it multiple times, which will affect the time of scab removal.
After the operation is completed, the face is cleaned with saline, and medical repair products or sterile facial masks can be applied for sedation Care.

Nursing time: once a month, 3-5 times as a course of treatment.
Note: After treatment, do not touch water for 24 hours. If you want to wipe it, you can wipe it with a disposable cotton swab with saline.

Redness, slight swelling, and fever may appear after treatment.
One day later: fever, redness and slight swelling due to physical fitness.
After 2 to 3 days: peeling, erythema or acne.
After 3 to 4 days: peeling and falling off naturally.



The handle is operated at 90 degrees vertically.


Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine
HOW TO OPERATE

Golden Microneedle Efficient Fractional RF Equipment for Acne, Wrinkle Removal Salon Medical Beauty Machine


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now