Professional 3 wavelength 532 1064 1320nm pico laser for tattoo removal
Working theory
Using the light blasting effect, the high-intensity laser penetrate the epidermis and can reach the pigment clusters in the dermis layer. Because the energy has a short time of action and the energy is extremely high, the pigment clusters will quickly expand and explode after absorbing the high energy in an instant. After the particles are swallowed by macrophages, excreted, and the pigment gradually fades and disappears.
The pico laser with ultra-short pulse width can effectively produce photo-mechanical effects and break the pigment particles into small fragments
Compared with nano-scale Q-switched laser, picosecond laser only needs lower energy to achieve the effect
It takes less number of treatment courses to achieve better treatment effect.
Stubborn green and blue tattoos can also be effectively removed
Treated but incomplete tattoo removal, picosecond laser can also treat
In the mechanism of pigment particle destruction, there are mainly photothermal and photomechanical effects. The shorter the pulse width, the weaker the effect of converting light into heat. Instead, the photomechanical effect is used, so picoseconds can effectively crush the pigment particles, Resulting in better pigment removal.
Application
Remove chloasma, freckles, age spots, brown mole spots, acne marks and other endogenous pigments, wash eyebrows, tattoos, moles, birthmarks, remove Ota moles, etc.
532nm: effective for tattoos(red and brown), reddish pigments and age spots.
1064nm: effective in treating endogenous pigmented skin lesions. Wash eyebrows, tattoos(dark and blue) and dark pigments, remove moles.
1320nm: shrink pores, whiten skin and lighten spots. Has obvious effects on the treatment of pigmented skin lesions such as tattoos, eyebrow tattoos, eyeliner, lip liner on exogenous pigmented skin, and traumatic tattoos.
Parameters
Laser Type |
YAG |
Wavelength |
1064nm, 1320nm, 532nm |
Spot Site |
1-5mm(adjustable) |
Energy |
10-1000Mj |
Output Mode |
Pulse |
Pulse Wide |
≤500 |
Frequency |
1-10Hz |
Warning Temperature |
45ºC(adjustable) |
Laser Power |
500W |
Input Power |
1200W |
Screen |
10.4inch touch screen |
Cooling System |
Water Cooling and Wind Cooling |
Voltage |
AC220V±10% 15A 50-60Hz, 110v±10%25A50-60Hz |
Product introduction
focus on pigment and tattoo removal
Freckles and moles remove
Pico laser advantages
Pico laser Internal structure
10.4 inch touch screen
independent control system
imported power supply
Operation show
Treatment steps
Before Treatment:
- Understand the previous treatment methods and check the skin condition to see if it is suitable for systemic treatment.
- Patients who have been exposed to prolonged sun exposure before or who have had artificial sunbathing within 48 hours are not acceptable for treatment.
- Patients with a history of herpes simplex in the area to be treated need to receive preventive medication before surgery.
- Discuss treatment goals with patients.
- Strict and effective eye protection must be provided to patients. Such as gauze, eyelid mask, etc.
- It is recommended to take pictures before and after the operation to record the treatment process. Taking pictures provides an objective basis to prove the therapeutic effect, because some patients cannot objectively judge the treatment process in the gradual therapeutic effect.
Washing Eyebrows
During the treatment, the customer should keep his eyes closed. The operator selects the required laser energy according to the color depth of the treatment area (adjust the energy value, the recommended energy value for the new machine is 35%), and slowly move the handle from the normal skin near the treatment area to the treatment area to let the customer has a psychological acceptance process. At this time, the frequency can be set to 3Hz, and the head is 1-2 fingers away from the treatment area. The treatment can be performed from the end of the eyebrow or the eyebrow. If there is a phenomenon of color reversion within 5-10 minutes after treatment, it can be washed again. Re-examination after one and a half months, if the pigment has not faded, the second treatment can be performed(If the color becomes light and does not absorb energy, it can be operated with activated carbon liquid to help absorb energy).
Tattoo Removal
The frequency can be set to 3Hz-5Hz, and the distance between the tip of the handle and the treatment area is 3-4 fingers, and the treatment is performed with high energy as close to the focus point as possible. Common black and blue tattoo, choose 1064nm bald head treatment, in case of red or coffee, choose 532nm bald head treatment, the treatment interval is 45-90 days, and the treatment is cycled until it is washed (if the color becomes light and does not absorb energy, it can be operated with activated carbon liquid. To help absorb energy).
Freckle Removal
Facial freckle can be treated with activated carbon. The frequency is set to 3Hz, the recommended energy is 60%-80%, and the 1064nm high beam head is used. The head is 40cm away from the skin for treatment. After finishing the whole face, if there are some areas with heavier spots, you can skip the activated carbon and use the focus energy, but there should be no bleeding, just slightly red. About 7 days after the operation, if the color becomes darker, it is recommended to use a depigmentation cream to help decompose the pigment. (Focus: the point with the loudest blasting noise.)
Mole Removal
The frequency can be set to 3Hz-5Hz, and the distance between the head and the treatment area is 3-4 fingers, and the treatment is performed with high energy as close to the focus point as possible. Choose 1064nm bald head treatment, the treatment interval is 45-90 days, and the treatment is cycled until it is washed (if the color becomes light and does not absorb energy, it can be operated with activated carbon liquid to help absorb energy).
Pore Shrinking
Activated carbon powder must be used to treat shrinkage of pores. The frequency is set to 3Hz-5Hz, and the recommended energy is 60%. When the 1320nm head is used, the distance between the head and the skin is 4cm, and the frequency can be set to 3Hz-4Hz. After finishing treatment, there is still some heat inside, the pores are expanded by heat, and the effect is not visible. It takes about 2 days to see better results.