Blue and black case 3 wavelength 755 808 1064nm all skin colors painless diode laser hair removal Working principle Semiconductor lasers are stacked with ultra-micro semiconductor laser chips. The basic treatment principle is biological effect. The 755nm 808nm 1064nm laser emitted by this machine is easily absorbed by colored hair follicles without damaging the epidermal tissue. The energy emitted by the light is absorbed by hair and pigments in hair follicles. After being converted into heat, the temperature of the hair follicles is increased. When the temperature rises to a certain level, the hair follicles will be irreversibly damaged.The cooling temperature can reach minus 20 degree.After a period of time, the damaged hair follicles will be removed with the body's metabolism to achieve the purpose of permanent hair removal. Modern design, stable output, short exposure time, good effect of permanent hair removal, high safety
755&808&1064&nm for all skin type,755nm for white skin,1064nm for black or dark skin hair and 808nm for other skin type colourful hair remove
Application Long-lasting hair removal, better than IPL and E-light; effectively remove hair on different parts of the body, such as face, underarms, back, legs and bikini line, effectively removing hair of various depths. Effectively remove hairs of different colors and textures, such as black, auburn and brown. Permanent hair removal, suitable for a variety of skins. Non-invasive treatment method, high safety. It is painless and non-invasive, and does not need a recovery period, and does not affect normal life and work.
Specifications
Best configuration 3 wavelength 755 808 1064nm diode laser hair removal machine show 3 wavelength 755 808 1064nm suitable for different skin type
Input 2000W for machine,600W for handle with 10 bars
fast hair remove
permanent haur remove and painless
Details show 10.4inch touch screen
handheld gun handle
Treatment area introduction hand,leg,underarmsface and bikini line
For Man from I-V 5 skin colors ,from light to dark color for option,the same as woman operation
Treatment steps: Before Treatment:
Understand the previous treatment methods and check the skin condition to see if it is suitable for systemic treatment.
Patients who have been exposed to prolonged sun exposure before or who have had artificial sunbathing within 48 hours are not acceptable for treatment.
Patients with a history of herpes simplex in the area to be treated need to receive preventive medication before surgery.
Discuss treatment goals with patients.
The treatment parameters depend on the skin type, the color, type, density and depth of the treated hair. Once the treatment parameters are selected, shave, clean the treatment area, and remove any hair and debris that may affect the treatment.It is recommended to take pictures before and after the operation to record the treatment process. Taking pictures provides an objective basis to prove the therapeutic effect, because some patients cannot objectively judge the treatment process in the gradual therapeutic effect Cleaning: Before doing treatment, clean and disinfect the treatment area. Shaving hair away: For better energy transmit to skin, need to shave the exposed hair away(remaining 1-1.5mm). Daub cooling gel: Cooling gel can reduce discomfort during treatment, so before starting treatment, daub proper cooling gel onto treatment area (normal 2mm thickness) Set parameters for device: Gradually set pulse width and corresponding power, frequency to achieve the best experience. The treatment parameters are set by the skin type, the hair color, type, density and depth of the treated area. Hair depilation: The method to do hair depliation: the hand-piece (sapphire) is stick to skin tightly, and sliding 6-7 times back and forth; during this treatment, observe the changes of skin: if skin no obvious changes,need to increase power until user feels hot and the skin on treatment area appears flushed. Cleaning and Ice compress: Aftertreatment, cleanthe treatment area, and do ice compress to partial skin for 10-15 minutes if needed; for device, return to menu from treatment screen, turn off device with key switch and clean the sapphire with tissue. Cleaning and Ice compress: Aftertreatment, cleanthe treatment area, and do ice compress to partial skin for 10-15 minutes if needed; for device, return to menu from treatment screen, turn off device with key switch and clean the sapphire with tissue.
Depending on the hair growth cycle and the treatment site, 28 days is recommended as a course of treatment, and 4-6 courses are enough.
Under normal circumstances, users can check and receive more treatment within 4-6 weeks after surgery. According to different treatment effects, personal hair growth cycle, this period will be different.
If no more treatment is needed, the user should be checked again after 3-4 months or if there is hair regrowth in the treated area.
If part of the hair is removed, the user should receive a treatment check again after 4-6 weeks if necessary.
If no changes are observed, the treatment parameters need to be changed, multiple treatments, and the interval time increased to allow new hair growth in the treated area. New growth in different parts of the body (growth cycle), different individuals (gender, hormones) are different.