• 6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment
  • 6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment
  • 6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment
  • 6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment
  • 6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment
  • 6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment

6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment

Type: Tattoo Removal
Theory: Laser
Application: Salon, Home
Portable: Non Portable
Laser Power: 500W
Rated Power: 1200W
Customization:
Diamond Member Since 2012

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
BR302
Screen
10.4inch
Output Mode
Pulse Output
Laser Type
Solid Laser(YAG)
Spot Area
1-5mm(Adjustable)
Control Mode
Touch Control
Total Times of Laser
Not Resettable
Pulse Width
500 Picoseconds
Energy
10-1000mj Decimal System
Wavelngth
532nm 1064nm 1320nm
Working Heads
6PCS Changeable Heads
Working Water Temperature
16-45 Degrees
Machine Size
32*50*75cm
Frequency
1-10Hz
Transport Package
Aluminum Case
Specification
packing size: 49*63*93cm
Trademark
BEIR
Origin
Guangzhou
HS Code
90189090
Production Capacity
300 PCS/Month

Product Description

6 changeable heads ND Yag laser tattoo removal beauty equipment
Working principle
Using the light blasting effect, the high-intensity laser penetrate the epidermis and can reach the pigment clusters in the dermis layer. Because the energy has a short time of action and the energy is extremely high, the pigment clusters will quickly expand and explode after absorbing the high energy in an instant. After the particles are swallowed by macrophages, excreted, and the pigment gradually fades and disappears.
The picosecond laser with ultra-short pulse width can effectively produce photo-mechanical effects and break the pigment particles into small fragments

Compared with nano-scale Q-switched laser, picosecond laser only needs lower energy to achieve the effect
It takes less number of treatment courses to achieve better treatment effect
Stubborn green and blue tattoos can also be effectively removed
Treated but incomplete tattoo removal, picosecond laser can also treat
In the mechanism of pigment particle destruction, there are mainly photothermal and photomechanical effects. The shorter the pulse width, the weaker the effect of converting light into heat. Instead, the photomechanical effect is used, so picoseconds can effectively crush the pigment particles, Resulting in better pigment removal.

6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment


Application
Remove chloasma, freckles, age spots, brown mole spots, acne marks and other endogenous pigments, wash eyebrows, tattoos, moles, birthmarks, remove Ota moles, etc.
532nm: effective for tattoos(red and brown), reddish pigments and age spots.

1064nm: effective in treating endogenous pigmented skin lesions. Wash eyebrows, tattoos(dark and blue) and dark pigments, remove moles.
1320nm: shrink pores, whiten skin and lighten spots. Has obvious effects on the treatment of pigmented skin lesions such as tattoos, eyebrow tattoos, eyeliner, lip liner on exogenous pigmented skin, and traumatic tattoos.
6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment


Product show
pico laser tattoo remove 
salon best wanted product

6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment

Details show
6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment
6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment

6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment

6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment

6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment
Application
one machine can solve the skin problems as below 
freckle,acne and scars,tattoo,skin rejuvenation,eyebrows,mole washing

6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment

Advantages
6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment

6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment
6 Changeable Heads ND YAG Laser Tattoo Removal Beauty Equipment

Treatment steps

Before Treatment:
  • Understand the previous treatment methods and check the skin condition to see if it is suitable for systemic treatment.
  • Patients who have been exposed to prolonged sun exposure before or who have had artificial sunbathing within 48 hours are not acceptable for treatment.
  • Patients with a history of herpes simplex in the area to be treated need to receive preventive medication before surgery.
  • Discuss treatment goals with patients.
  • Strict and effective eye protection must be provided to patients. Such as gauze, eyelid mask, etc.
  • It is recommended to take pictures before and after the operation to record the treatment process. Taking pictures provides an objective basis to prove the therapeutic effect, because some patients cannot objectively judge the treatment process in the gradual therapeutic effect.

 Washing Eyebrows
During the treatment, the customer should keep his eyes closed. The operator selects the required laser energy according to the color depth of the treatment area (adjust the energy value, the recommended energy value for the new machine is 35%), and slowly move the handle from the normal skin near the treatment area to the treatment area to let the customer has a psychological acceptance process. At this time, the frequency can be set to 3Hz, and the head is 1-2 fingers away from the treatment area. The treatment can be performed from the end of the eyebrow or the eyebrow. If there is a phenomenon of color reversion within 5-10 minutes after treatment, it can be washed again. Re-examination after one and a half months, if the pigment has not faded, the second treatment can be performed(If the color becomes light and does not absorb energy, it can be operated with activated carbon liquid to help absorb energy).

 Tattoo Removal
The frequency can be set to 3Hz-5Hz, and the distance between the tip of the handle and the treatment area is 3-4 fingers, and the treatment is performed with high energy as close to the focus point as possible. Common black and blue tattoo, choose 1064nm bald head treatment, in case of red or coffee, choose 532nm bald head treatment, the treatment interval is 45-90 days, and the treatment is cycled until it is washed (if the color becomes light and does not absorb energy, it can be operated with activated carbon liquid. To help absorb energy).

 Freckle Removal
Facial freckle can be treated with activated carbon. The frequency is set to 3Hz, the recommended energy is 60%-80%, and the 1064nm high beam head is used. The head is 40cm away from the skin for treatment. After finishing the whole face, if there are some areas with heavier spots, you can skip the activated carbon and use the focus energy, but there should be no bleeding, just slightly red. About 7 days after the operation, if the color becomes darker, it is recommended to use a depigmentation cream to help decompose the pigment. (Focus: the point with the loudest blasting noise.)

 Mole Removal
The frequency can be set to 3Hz-5Hz, and the distance between the head and the treatment area is 3-4 fingers, and the treatment is performed with high energy as close to the focus point as possible. Choose 1064nm bald head treatment, the treatment interval is 45-90 days, and the treatment is cycled until it is washed (if the color becomes light and does not absorb energy, it can be operated with activated carbon liquid to help absorb energy).

 Pore Shrinking
Activated carbon powder must be used to treat shrinkage of pores. The frequency is set to 3Hz-5Hz, and the recommended energy is 60%. When the 1064nm far focus bald head is used, the distance between the head and the skin is 4cm, and the frequency can be set to 3Hz-4Hz. After finishing treatment, there is still some heat inside, the pores are expanded by heat, and the effect is not visible. It takes about 2 days to see better results.


6. Cautions
(1) After treatment, the skin is sensitive to heat, so avoid using hot water to clean the treatment area when washing your face. You should use warm or cold water to clean the area. When washing, the action should be as gentle as possible and do not rub hard.
(2) At the moment when the strong light acts during treatment, a large amount of free water on the skin is lost, most patients will feel the skin is dry and dehydrated, so after treatment, it is necessary to replenish water in time.
(3) During the recovery period, the treatment area should be kept dry, do not perform skin care, do not make up and rubbing.
(4) Strenuous exercise should not be performed during the recovery period, so as to avoid excessive sweating, causing skin infections or delaying the repair process.
(5) After treatment, apply ice or cold spray according to the severity of skin reaction.
(6) Photosensitivity foods and drugs are forbidden during treatment.
(7) The crusted skin during the recovery period will usually fall off on its own in about 7-10 days. It cannot be peeled off by hand to avoid pigmentation or scars.
(8) Pay attention to sun protection during the recovery period and use umbrellas when going out.








 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now