Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator

Product Details
Customization: Available
Type: Hair Removal Instrument
Theory: Laser
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 10 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (25)
  • Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator
  • Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator
  • Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator
  • Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator
  • Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator
  • Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • Before And After
Overview

Basic Info.

Model NO.
DL816
Portable
Non Portable
Product Name
Diode Laser Beauty Machine
Function
Painless Hair Removal
Power
2000W
Handle Power
600W with 10 Bars
Shots
10 Millions
Spot Size
12mm*24mm
Energy Density
1-100j/Cm2
Pulse Width
20-500ms
Frequency
1-10Hz
Screen
12 Inch Touch Screen
Pacakge
Wooden Case
Warranty
12 Months
Transport Package
Wooden Case with EPE Inside
Specification
117*52*56cm
Trademark
BEIR
Origin
Guangdong
HS Code
8543709990
Production Capacity
300PCS/Month

Product Description

freezing point laser hair removal device 810nm ice cooling laser hair removal Epilator

Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator
 
Wavelength 808nm
Mode Pulse Mode
Spot Size 12mm*24mm
Temperature 0-30 degree
Energy Density 1-100J/cm2
Pulse Width 20-500ms
Frequency 1-10Hz
Laser Power 600W
Input Power 2000W
Screen 12inch touch screen
Cooling System Water cooling+ Wind cooling+ TEC electronic cooling
Voltage AC220V±10% 15A 50-60HZ, 110v±10% 25A50-60HZ
Product Description

Working Theory

Semiconductor lasers are stacked with ultra-micro semiconductor laser chips. The basic treatment principle is biological effect. The 808nm laser emitted by this machine is easily absorbed by colored hair follicles without damaging the epidermal tissue. The energy emitted by the light is absorbed by hair and pigments i hair follicles. After being converted into heat, the temperature of the hair follicles is increased. When the temperature rises to a certain level, the hair follicles will be irreversibly damaged. After a period of time, the damaged hair follicles will be removed with the body's metabolism to achieve the purpose of permanent hair removal. Modern design, stable output, short exposure time, good effect of permanent hair removal, high safety.


Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator

Product Parameters

 

Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator
Our Advantages
Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal EpilatorFreezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator

 

Before And After

Freezing Point Laser Hair Removal Device 810nm Ice Cooling Laser Hair Removal Epilator
Treatment Course


Underarm, Face: Treatment interval---4-6 weeks;
Arms and legs, body: Treatment Interval----4-6 weeks;
Treatment Period: 4-6 times.

***Depending on the hair growth cycle and the treatment site, 28 days is recommended as a course of treatment, and 4-6 courses are enough.
***Under normal circumstances, users can check and receive more treatment within 4-6 weeks after surgery. According to different treatment effects, personal hair growth cycle, this period will be different.
***If no more treatment is needed, the user should be checked again after 3-4 months or if there is hair regrowth in the treated area.
***If part of the hair is removed, the user should receive a treatment check again after 4-6 weeks if necessary.
***If no changes are observed, the treatment parameters need to be changed, multiple treatments, and the interval time increased to allow new hair growth in the treated area. New growth in different parts of the body (growth cycle), different individuals (gender, hormones) are different.



Suggested Parameters

The following suggestions are for reference only, and customers in different regions should make reasonable adjustments.

1. Single Point Treatment
Set the low frequency to 1Hz and set the higher energy at the same time. The machine is set with factory default parameters, and the user can adjust it according to different situations, but please adjust the energy instead of frequency. In this mode, the pulse width will be automatically adjusted when you adjust the energy.
500W parameters, 300W energy plus 80% pulse width unchanged

 

Men White Skin Yellow Skin Brown Skin Black Skin
Parameters Energy 70J/cm2 65J/cm2 50J/cm2 55J/cm2
Pulse Width 5-100ms 5-80ms 5-80ms 5-80ms
Frequency 1-4Hz 1-5Hz 1-5Hz 1-5Hz


2. Sliding Therapy

Set the frequency to 6HZ and set a lower energy. When using this treatment method, the therapist does not need to adjust the parameters, but only needs to choose the number and time of treatment according to the patient's feeling.
500W parameters, 300W energy plus 80% pulse width unchanged


 

Treatment Parameters Energy: 20J/cm2; Frequency: 6Hz; Pulse Width:50ms
Men and Women White Skin Yellow Skin Brown Skin Black Skin
Beard Sliding Speed 3cm/s 3cm/s 5cm/s 5cm/s
Cumulative treatment time every 0.5min, 5cm2 every 0.5min, 5cm2 every 1min, 5cm2 every 1min, 5cm2
Armpit Sliding Speed 3cm/s 3cm/s 5cm/s 5cm/s
Cumulative treatment time every 1min, 5cm2 every 1min, 5cm2 every 1.5min, 5cm2 every 2min, 5cm2
Hairline Sliding Speed 2cm/s 2cm/s 1cm/s 1cm/s
Cumulative treatment time every 0.5min, 5cm2 every 0.5min, 5cm2 every 0.5min, 5cm2 every 0.5min, 5cm2
Bikini Sliding Speed 2cm/s 2cm/s 1cm/s 1cm/s
Cumulative treatment time every 1min, 5cm2 every 1min, 5cm2 every 1.5min, 5cm2 every 1.5min, 5cm2
Thigh Sliding Speed 3cm/s 3cm/s 5cm/s 5cm/s
Cumulative treatment time every 1min, 5cm2 every 1min, 5cm2 every 1.5min, 5cm2 every 1.5min, 5cm2
Calf Sliding Speed 3cm/s 3cm/s 5cm/s 5cm/s
Cumulative treatment time every 1min, 5cm2 every 1min, 5cm2 every 1.5min, 5cm2 every 1.5min, 5cm2

 




Treatment parameter is adjusted by following principles:

Pulse width at 80ms:
Power from 6-20J/cm2 adjustable;
Frequency from 1-5Hz adjustable.

Pulse width at 120ms:
Power from 6-30J/cm2 adjustable;
Frequency from 1-3Hz adjustable.

Pulse width at 160ms:
Power from 8-40J/cm2 adjustable;
Frequency from 1-2Hz adjustable.

Pulse width at 200ms:
Power from 10-50J/cm2 adjustable;
Frequency from 1-2Hz adjustable.


Power and Frequency will change based on different pulse width.


More information please feel free to contact us

Fiona Liu

 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier